Abstract
A simple and isocratic reverse-phase liquid chromatography with mass spectrometric method has been developed and validated for the determination of heptaethylene glycol monomethyl ether in benzonatate drug substance. Benzonatate is an oral antitussive drug used to relieve and suppress cough in patients older than 10 years. The presence of residual heptaethylene glycol monomethyl ether in the benzonatate drug substance affects the safety, strength, purity and quality of the drug substance. The subject compound separation was achieved using 0.1% formic acid and acetonitrile (50:50 v/v) at a flow rate of 0.3 ml/min. The Suplex PKB-100 250 × 4.6 mm, 5 μm LC column was used for a better peak shape. Detection was carried out at an m/z value of 341. The linearity curve showed a correlation of coefficient of >0.999. The precision and intermediate precision (RSD) were <7.30. The accuracy values were >90% for all levels. The developed method was validated as per International Conference on Harmonization guidelines and found to be a novel, specific and sensitive analytical method for determination of components of interest.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.