Abstract
A rapid, simple, and reliable HPLC method was developed and validated to determine the presence of ferrocyanide ions (FeCNs) in food grade salts. An analytical column coupled with a guard column and mobile phase comprised of sodium perchlorate and sodium hydroxide (NaOH) were employed at a detection wavelength of 221nm. Samples were dissolved in 0.02M NaOH solution and filtered. For processed salts including herbs and spices, a C18 cartridge was applied to minimize interference from salt matrices. The method validation was based on linearity, accuracy (recovery), precision, LOD, LOQ, and measurement uncertainty. This method exhibits good linearity from 0.1−10mg/L (r2=0.9999). The LOD and LOQ values were determined to be 0.02 and 0.07mg/kg, respectively. The FeCN recoveries in six salt matrices ranged from 80.3−102.2% (RSD=0.3–4.4%). These results indicate that the proposed method is suitable for FeCN ion determination in various food grade salts.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.