Abstract

Two validated methods for the simultaneous determination of ibuprofen and famotidine in the presence of ibuprofen impurity (4-isobutylacetophenone) and or famotidine degradation products were described. The first method was a simple TLC method where separation was performed on silica gel platesusing ethyl acetate: methanol: ammonia (9:2:1, by volume) as a mobile phase. Rf values were found to be 0.40, 0.94, 0.66, 0.27, 0.83 for ibuprofen, 4-isobutylacetophenone, famotidine, famotidine acid and basic degradation products, respectively. The second method is by HPLC on C18 column using methanol: phosphate buffer pH 3 (80:20, v/v) as a mobile phase. Retention times were found to be 2.2, 9.9, and 8.6 for famotidine, ibuprofen, and 4-isobutylacetophenone, respectively. Both methods were validated according to the ICH guidelines and applied for the determination of the two drugs in pure powder and combined dosage form without interference from the excipients.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.