Abstract
Abstract A simple, rapid, low-cost, and sensitive high-performance liquid chromatographic method was developed to determine tildipirosin in horse plasma. Plasma samples were extracted with diethyl ether, and after evaporation, tildipirosin was determined by reverse-phase chromatography with an ultraviolet detector set at a wavelength of 289 nm. Tildipirosin was separated on a Zorbax Eclipse XDB-C18 column, 150 x 3.0 mm, 5 μm with gradient chromatographic elution. The retention times were 3.0 min and 6.4 min for tildipirosin and tylosin tartrate, respectively. The total run time was 9 minutes in this method. Calibration curves ranged from 0.1 to 3 μg/mL. The lower limit of detection for plasma was0.035μg/mL, and the lower limit of quantitation was 0.1 μg/mL. Both accuracy and precision were always < 12% exce pt for LLOQ < 20%. Mean recovery was 99.5 %. This procedure can be applied to determine tildipirosin concentrations in plasma and be useful to perform pharmacokinetic studies.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.