Abstract

Tuberculosis treatment consists of a fixed dose combination of rifampicin (RIF), isoniazid (INH), pyrazinamide (PYZ), and ethambutol hydrochloride (EMB). The combined treatment using various drugs is necessary for patient curing, without recrudescence, and for prevention of drug-resistant mutants, which may occur during treatment. An HPLC-diode array detector (DAD) method for the simultaneous determination of RIF, INH, PYZ, and EMB in fixed dose combination tablets was developed and validated. Chromatographic experiments were performed on an Agilent 1200 HPLC system, and the separation was carried out on a Purospher STAR RP18e (250×4.6 mm id, 5 μm, Merck) analytical column. Gradient elution was carried out with a mobile phase of 20 mM monobasic sodium phosphate buffer with 0.2% triethylamine (pH 7.0) and acetonitrile at a flow rate of 1.5 mL/min. The total run time was 12 min, and the re-equilibration time was 5 min. EMB detection was performed at 210 nm, and RIF, INH, and PYZ were detected at 238 nm, using a DAD. The method proved to be specific, linear (r2>0.99), precise (RSD<2%), accurate, and robust and may be applied to the QC analysis of pharmaceutical formulations.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.