Abstract

An assay for quantifying viability in BCG vaccine by determining intracellular ATP content was developed and validated. ATP content was determined by measuring bioluminescence in the presence of luciferin/luciferase. During development and validation the ATP method was compared to the conventional viable count method. A key step to obtain correlation between ATP content and CFU was found to be a period of pre-incubation in a growth medium before ATP determination. During the validation, the robustness, linearity, accuracy, precision, and range were studied. The method validation study showed that the method applied was robust and applicable to determine ATP content in lyophilised BCG for estimating viability in the BCG samples. By comparison with a conventional viable count method, a high correlation between ATP content and the viable count was found; this relationship can be applied in routine quality control to estimate viable count from the ATP content determined in a sample.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.