Rationale: A simple, sensitive, reliable, validated, inductively coupled plasma mass spectrometric method for the determination of aluminium and magnesium using a simple common microwave-assisted digestion sample preparation technique for a few commonly used formulations was developed and validated according to International Conference on Harmonization Q3D and the United States Pharmacopeia general chapter <232> and <233>. The following pharmaceutical dosage forms were considered for estimation of aluminium and magnesium: Alumina, magnesia simethicone oral suspension, Alumina, magnesia simethicone chewable tablets, alumina and magnesia oral suspension, alumina and magnesium carbonate oral suspension. Methods: The methodology included optimizing a common microwave assisted digestion method, selecting the isotopes, choosing the measurement technique, and designating internal standards. The finalized microwave assisted procedure was a two-step program where in the first step the samples were ramped for 10 min to a temperature of 180 °C and hold for 5 min followed by ramping for 10 min to a temperature of 200 °C and hold for 10 min. Magnesium (24Mg) and aluminium (27Al) isotopes were finalized, internal standard assigned for both the isotopes was yttrium (89Y) with Helium (kinetic energy discrimination-KED) as the measuring mode. System suitability was run before initiating analysis to ensure that system performance was consistent. Results: Analytical validation parameters like specificity, linearity (from 25% to 200% of sample concentration), the detection limit and the limit of quantification were established. For all these dosage forms, the method's precision was demonstrated by analyzing the percentage relative standard deviation for six injections. Accuracy was established from 50% to 150% of instrument working concentration (J-levels) for aluminium and magnesium for all the formulations and was found to be within the range of 90-120%. Conclusion: This common analysis method, along with the common microwave-digestion technique applies to numerous types of matrices for a finished dosage form with aluminium and magnesium.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.