Abstract

Abstract Triclabendazole is one of the main drugs used to treat liver fluke in livestock. A rapid LC-MS/MS method was developed and validated to determine ovine plasma levels of triclabendazole sulfoxide. A Gemini NX-C18 column was used to achieve analytical separation, with gradient elution of a mobile phase composed of 0.1% formic acid in acetonitril and 0.1% formic acid in water at flow rate of 0.6 mL/min. MRM with positive ESI ionization was used for the detection of triclabendazole sulfoxide (m/z 360.10 from m/z 376.97). Fenbendazole was used as internal standard. Plasma protein precipitation with acetonitrile was used for sample processing. The method was validated with regards to selectivity, linearity (r > 0.9939), within run and between run precision (CV < 8.9%) and accuracy (bias < 8.9%) over the concentration range 1–100 µg/mL plasma. The method developed is simple, selective and can be applied in bioequivalence and bioavailability studies.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call