Abstract

To develop and validate a novel scoring system for predicting the risk of uterine perforation during brachytherapy (BT) in cervical cancer patients and to stratify patients based on this score to guide the use of ultrasound guidance during BT. Fifty patients with uterine perforation during BT between January 2018 and December 2020 were included. Common reasons for perforation were identified and a scoring system was developed. This was then applied to a cohort of 50 patients without perforation. The 2 cohorts were compared using the χ² test. To validate the scoring system, all newly diagnosed patients who underwent BT in 2021 were scored, and analysed using χ² test and receiver operator characteristic curves. The mean score in the test cohort was 10.16 (range=7-14) and 5.92 (range=5-8) for patients with and without perforation. In the validation cohort, the mean score was 6.9 (range=5-10) and 9.33 (range=7-11) for those with and without perforation. Patients with a score <8 were classified as low risk, while those with a score ≥8 were classified as high risk. Among the criteria evaluated for validation, response to external beam radiotherapy, uterine position, cervico-uterine angle (uterine flexion), identification of cervical os at BT assessment, and the total score were significant predictors, while previous history of perforation, uterine length, and additional uterine anomaly were not. The novel scoring system is an effective predictor of perforation risk during BT. Implementing this during BT assessment can optimize the need for ultrasound guidance during the procedure.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call