Abstract

This work shows a new analytical method (ion pair HPLC) for the analysis of Bisoprolol Fumarate (BIS) and Carvedilol (CAR) in bulk and tablet. The developed analytical method has been carried out on an Inertsil ODS-3 5µL column 4.6 X 250 mm (w), as stationary phase using a mobile phase {Acetonitrile/ water 50/50 (v/v) containing sodium heptane sulfonic salt 0.001M as Ion pair agent}. The detection wavelength was 223 nm and the flow rate was 1.5 mL /min. Retention times were 3.5 min of BIS and 5.8 min of CAR. The analytical method has been validated by ICH guidelines. The developed method gave linearity in the concentration range of 20–60 µg/ mL accuracy with mean recovery values between 98-102 % (99.73% for BIS and 101.2% for CAR). The developed method is useful for separating and determining Bisoprolol Fumarate and Carvedilol in their pharmaceutical forms.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.