Abstract
Introduction. Metoprolol is a cardioselective blocker of β-adrenergic receptors. Drugs containing metoprolol have hypotensive, antianginal, antiarrhythmic effects. Moderately dangerous when taken orally, has a general toxic effect. Metoprolol is produced in two forms: in the form of salts of tartaric and succinic acids, the approximate safe level of exposure to which is 0.3 mg/m3. To ensure the safety of workers, it is necessary to carry out sanitary and hygienic air control. Methods for the quantitative analysis of metoprolol in the air of the working area, presented in the current scientific literature, allow monitoring only for metoprolol salts in the form of tartrate. 
 The aim of the study is to develop and validate an analytical method for the quantitative determination 
 of metoprolol succinate in the air of the working area by HPLC-MS. 
 Materials and methods. For the analysis, standard samples of metoprolol succinate and air samples taken at all stages of the life cycle of the production of the drug metoproolol were used. Chromatographic separation and detection were performed on an Agilent 1260 Infinity G6125B high performance liquid chromatograph (Agilent Technologies, USA) equipped with a column and sample thermostat, a degasser, a pump, an autosampler, and a G6125B mass selective detector. A Waters Xbridge® C18 3.5 µm column was used; 2.1×30 mm (Waters, Ireland). Primary data were processed using Open Lab CDS ChemStation Edition (Rev. C.01.07 SR3) software (Agilent Technologies, USA).
 Results. A method for the quantitative determination of metoprolol succinate in air samples by HPLC-MS has been developed and validated. During the validation of the developed methodology, it was found that the validation characteristics (specificity, linearity, accuracy and precision, correctness, reproducibility) are within the acceptance criteria. The analytical range of the technique was 0.1–10.0 µg/ml and allows the developed technique to be used to control the average shift MPCs in the air of the working area.
 Limitations. The results of the study of the air in the working area are applicable only to the production of the drug metoprolol in the form of tablets; the study of air during the synthesis and packaging of the active pharmaceutical substance was not carried out. 
 Conclusion. An analysis of air samples from the production of the drug metoprolol was carried out and the safety of working conditions was proved.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.