Abstract

Natural estrogens (estrone: E1, 17β-estradiol: E2, estriol: E3) and the synthetic estrogen (17α-ethinylestradiol: EE2) are endocrine disruptors harmful to aquatic wildlife. The European Commission included these molecules in the surface water Watch Lists issued in 2015 and 2018 under the Water Framework Directive regarding emerging aquatic pollutants, proposing maximum detection limits (LOD) of 0.035 ng/L for EE2 and 0.4 ng/L for E1 and E2. Attaining these limits represents a challenge even with the most up-to-date analytical tools, in particular in surface water. A two-step sample preparation, involving a preliminary extraction of a whole water sample on a solid-phase extraction (SPE) disk and further purification on a Florisil SPE cartridge, was optimized. The purified extract was derivatized subsequently and quantified by LC-MS/MS. The main goal was to maximize the recoveries to achieve the very low LODs required by the European Watch Lists. The method was fully validated in seven surface water. The LODs calculated were below the maximum acceptable limits required by the European Commission.

Full Text