Abstract

Objective: The study aimed to development and validation of simple, precise, and reliable high-performance thin-layer chromatography (HPTLC) for the determination of terbutaline sulfate (TBS), bromhexine hydrochloride (BRH), and etophylline (ETP) in pharmaceutical dosage form.
 Methods: A simple, precise, rapid, and accurate HPTLC method was developed for the estimation of TBS, BRH, and ETP in pharmaceutical dosage form. Pre-coated silica gel G60 F254 aluminum sheet (10 cm2×10 cm2 and thickness 0.2 mm) was used as stationary phase while mobile phase consisting of benzene: methanol:glacial acetic acid 8:0.5:1.5 v/v/v detection at 275 nm. The present method had validated according to ICH guidelines.
 Results: Migration distance found 80 mm at 275 nm. The retention factor found to be 0.24, 0.57, and 0.68, respectively. The detector response was linear in the concentration range of 60–210 ng/band, 2400–8400 ng/band, and 96–336 ng/band, respectively. The linear regression equation being Y=32.20x−562.9, Y=11.79x−1711, and Y=1.756x−5636, respectively. The limit of detection for TBS 0.677 μg, for BRH 8.123 μg, and for ETP 57.915 μg and limit of quantification to be 2.053, 24.617, and 175.5 μg, respectively, were found. The developed method validated by ICH guideline, i.e., accuracy, precision, robustness, specificity, and system suitability.
 Conclusion: In this study, we had developed a simple, fast, and reliable HPTLC method for the determination of TBS, BRH, and ETP in pharmaceutical dosage form.

Highlights

  • Terbutaline sulfate (TBS) is a selective beta-2 adrenergic agonist used as a bronchodilator and mucolytic; etophylline (ETP) is non-selective phosphor diesterase inhibitor and acts as cardiac stimulant and bronchodilator while bromhexine hydrochloride (BRH) is a mucolytic agent

  • Literature review revealed that the estimation of ternary mixture containing salbutamol sulfate, BRH, and ETP by thinlayer chromatography (TLC) method [1]

  • The linearity of response for the present method was determined by analyzing standard solution of TBS, ETP, and BRH which were determined in the range of 60–210 ng/band, 2400–8400 ng/band, and 96–336 ng/band, respectively (Fig. 3)

Read more

Summary

Introduction

Terbutaline sulfate (TBS) is a selective beta-2 adrenergic agonist used as a bronchodilator and mucolytic; etophylline (ETP) is non-selective phosphor diesterase inhibitor and acts as cardiac stimulant and bronchodilator while bromhexine hydrochloride (BRH) is a mucolytic agent. Estimation of TBS and BRH is reported in Indian pharmacopoeia while ETP reported in European pharmacopoeia. Literature review revealed that the estimation of ternary mixture containing salbutamol sulfate, BRH, and ETP by thinlayer chromatography (TLC) method [1]. An attempt made to develop economical and rapid HPTLC method for simultaneous estimation of TBS, BRH, and ETP in pharmaceutical dosage form

Methods
Results
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call