Abstract

The development and validation of a virtual generic 3D model of the distal femur using computer graphical methods is presented. The synthesis of the generic model requires the following steps: acquisition of bony 3D morphology using standard computed tomography (CT) imaging; alignment of 3D models reconstructed from CT images with a common coordinate system; computer graphical sectioning of the models; extraction of bone contours from the image sections; combining and averaging of extracted contours; and 3D reconstruction of the averaged contours. The generic models reconstructed from the averaged contours of six cadaver femora were validated by comparing their surface geometry on a point to point basis with that of the CT reconstructed reference models. The mean errors ranged from 0.99 to 2.5 mm and were in agreement with the qualitative assessment of the models.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call