Abstract

Lutein is a carotenoid with antioxidant activity that is present in various dosage forms. The bioavailability of carotenoid from oral dosage formulations depends on their release, dissolution and its permeability through the gastrointestinal tract. Here, a dissolution test was developed for evaluating formulations and the bioavailability was assessed. The test utilized a USP-apparatus II with rotations of 50, 75 and 100rpm in water with P80 at 1, 2 and 5% (w/v). A non-everted rat intestinal sac model was used in conjunction to assess the intestinal permeability. The most discriminative conditions were 100rpm in water with 2% polysorbate 80, which showed profile differences between two formulations. The intestinal permeation studies showed a lag-time and apparent permeability coefficient that were characteristic of highly permeable drugs. We suggest that a dissolution test can be an essential quality control tool for formulations containing compounds as lutein, although not mandatory by the regulation agencies.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.