Abstract

The acquisition of skills in penile prosthesis surgery has many limitations mainly due to the absence of simulators and models for training. Three-dimensional (3D) printed models can be utilized for surgical simulations, as they provide an opportunity to practice before entering the operating room and provide better understanding of the surgical approach. This study aimed to evaluate and validate a 3D model of human male genitalia for penile prosthesis surgery. This study included 3 evaluation and validation stages. The first stage involved verification of the 3D prototype model for anatomic landmarks compared with a cadaveric pelvis. The second stage involved validation of the improved model for anatomic accuracy and teaching purposes with the Rochester evaluation score. The third stage comprised validation of the suitability of the 3D prototype model as a surgical simulator and for skill acquisition. The third stage was performed at 3 centers using a modified version of a pre-existing, validated questionnaire and correlated with the Rochester evaluation score. We sought to determine the suitability of 3D model for training in penile prosthesis surgery in comparison with the available cadaveric model. The evaluation revealed a high Pearson correlation coefficient (0.86) between questions of the Rochester evaluation score and modified validated questionnaire. The 3D model scored 4.33 ± 0.57 (on a Likert scale from 1 to 5) regarding replication of the relevant human anatomy for the penile prosthesis surgery procedure. The 3D model scored 4.33 ± 0.57 (on a Likert scale from 1 to 5) regarding its ability to improve technical skills, teach and practice the procedure, and assess a surgeon's ability. Furthermore, the experts stated that compared with the cadaver, the 3D model presented greater ethical suitability, reduced costs, and easier accessibility. A validated 3D model is a suitable alternative for penile prosthesis surgery training. This is the first validated 3D hydrogel model for penile prosthesis surgery teaching and training that experts consider suitable for skill acquisition. Because specific validated guidelines and questionnaires for the validation and verifications of 3D simulators for penile surgery are not available, a modified questionnaire was used. The current 3D model for penile prosthesis surgery shows promising results regarding anatomic properties and suitability to train surgeons to perform penile implant surgery. The possibility of having an ethical, easy-to-use model with lower costs and limited consequences for the environment is encouraging for further development of the models.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call