Abstract

As a way to improve performance of ITER TF conductors, two types of cable-in-conduit conductors were developed in Korea with variations of conduit thickness resulting in the different void fraction of the conductors. The estimated void fractions of the conductors are 31% and 33%. Here we report the details of the TF conductor development and the performance test result of them carried out in SULTAN. Regarding the conductor development, the internal-Sn-processed strand characteristics, strand cabling, twist pitch and characteristics of the conduits for the conductors are presented. For an extended understanding of the conductor design and performance, the SULTAN test results are presented and the effect of the void fraction variations is discussed based on the results.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.