Abstract There are many examples of wells around the world today that are shut-in due to failure of the Surface Controlled Sub-surface Safety Valve (SCSSV). Whilst these valves are generally very reliable, the control line that runs to surface in the annulus is susceptible to plugging by contaminants in the hydraulic control fluid and also to corrosion, which causes leaks; both are outcomes that render the valve inoperable. The failure of the control line also means that the contingency solution of installing a Wireline Retrievable Surface Controlled Sub-surface Safety Valve (WR-SCSSV) is not possible. When a safety valve fails, the most common remedial solution today involves installing a Sub-surface Controlled Safety Valve (SSCSV), such as an ambient valve or storm choke. Whilst this solution is lower cost and more straightforward than performing a full rig-based well work over, it is not as safe. SSCSVs are directly influenced by changing well flow conditions, such as high flow rates, low pressures, or by water slugs, and thus are notoriously unpredictable in operation. Additionally, they are not controllable from surface and not fail-safe, which is undesirable from a well control and safety standpoint. By transmitting electromagnetic (EM) signals from surface to downhole, it is possible to control downhole hardware. A wireless controlled safety valve has been developed that can be retro-fitted into a well using conventional slickline intervention equipment and procedures. Being controllable from surface and of a fail-safe closed design, this valve offers both functional and safety advantages over existing SSCSV solutions. This new valve also offers a retro-fittable solution for wells having no hydraulic control line installed. In situations where a capillary string may need to be installed for foam or chemical injection purposes, it also provides an opportunity to free up the hydraulic control line. A prototype valve was subjected to qualification and functionality testing in accordance with a modified ISO 10432 test procedure. This testing was followed by installation in an onshore gas well for a 6 month trial that involved both flowing and injection phases. The valve was cycled and inflow-tested regularly and performed reliably, consistently and fully in accordance with specification throughout the trial period. This successful trial of a new wireless controlled safety valve marks the introduction of a more controllable and predictable alternative to an ambient valve or storm choke, minimises deferred production and increases the well's safety. Following the successful onshore trial, the valve is now considered ready for wide scale field application onshore and at the time of writing this paper, plans for performing a first trial on an offshore platform are well advanced.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.