Abstract
The lateral flow strip test for 19-nortestosterone is one kind of immunochromatographic assay. Nitrocellulose membrane was separately immobilized with goat anti-rabbit IgG (control line) and 19-NT-OVA conjugate (test line). Anti-19-NT polyclonal antibody labeled with colloidal gold particles acted as the detector reagent. The assay is qualitatively, not quantitatively, judged with positive or negative result. We tested the sensitivity of the strip using spiked swine urine, and each specimen was independently measured by LC/MS/MS. The sensitivity, measure by eye, was determined to be 200 ng/mL. The assay time was less than 15 min, and so suitable for on-site rapid test.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.