Abstract

The energy produced in Fast Breeder Test Reactor (FBTR) is transferred to feed water for generating superheated steam in once-through shell and tube type counter current steam generator (SG). Sodium and water/steam flow in shell and tube side respectively are separated by thin-walls of ferritic steel tubes. Material defects in these tubes can lead to leakage of water/steam into sodium, resulting in sodium water reactions leading to undesirable consequences. Detection of a leak at its inception, therefore, is important for the safe and reliable operation of the reactor. Monitoring hydrogen in sodium, produced during reaction of sodium with the leaked water or steam is a convenient way to accomplish this. Nickel diffuser based instrumentation has been developed for real time detection of steam generator leak of FBTR at Kalpakkam. Though the performance of the system has been satisfactory, the failure of Nickel diffuser cannot be ruled out. This paper deals with the development and deployment of a miniature Mutual Inductance (MI) type leak detector for detection of sodium leak resulting from failure/rupture of the Nickel diffuser tubes in the SG leak detection system in FBTR.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call