Abstract
In order to simulate the characteristics of underwater shield tunnels, a new large-scale model test system with high water pressure and high stress loading capacity was developed. The loading control mode of the hydraulic system can perform uniform loading and gradient loading. Moreover, the vertical and horizontal hydraulic loading can reach 0·8 MPa and 1·6 MPa. The water pressure loading system has a maximum capacity of 0·5 MPa. Based on an actual project, a model test of an underwater shield tunnel lining under real soil and water pressure conditions was carried out. New segment joints of the model were developed during the model testing. The lateral pressure coefficient at rest of the model strata was slightly larger than 0·5, and close to that of the field strata. It was also found that the water pressure had a reducing effect on the soil pressure under large buried depth and high water pressure conditions. This system can mostly meet the requirements of underwater or underground engineering model tests.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Proceedings of the Institution of Civil Engineers - Structures and Buildings
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.