Abstract

The objective of this study was to develop and analytically validate an ELISA for the measurement of alpha1-proteinase inhibitor (α1-PI) in serum and faeces from cats. Lower detection limit, linearity, accuracy, precision, reproducibility, and reference intervals were determined. The lower detection limits were 0.02g/L for serum and 0.04μg/g for faeces. The observed-to-expected (O/E) ratios for serial dilutions of serum and faecal samples ranged from 100.0 to 129.7% (mean±SD: 112.2±9.9%) and 103.5 to 141.6% (115.6±12.8%), respectively. The O/E ratios for samples spiked with seven known concentrations of α1-PI ranged from 82.3 to 107.8% (94.7±7.6%) for serum, and 78.5 to 148.7% (96.8±18.2%) for faeces. The coefficients of variation for intra-assay and inter-assay variability were <7.9% and <12.1% for serum, and 5.3%, 11.8%, 14.2%, and 7.7%, 10.2%, 20.4% for faeces, respectively. Reference intervals were 0.6–1.4g/L for serum and upto 1.6μg/g for faeces. We conclude that this ELISA is sufficiently linear, accurate, precise, and reproducible for clinical evaluation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.