Abstract
ABSTRACT Oxygen (O2) sensors have been developed for in situ measurement of O2 in high-solids degradation processes. The O2 sensor has been shown to withstand the corrosive environment of the biodegradation process with high humidity and temperatures exceeding 60 oC. Calibration tests prior to and after in situ operation showed the sensor to perform accurately and reproducibly after 71 days of in situ operation. A linear relationship between O2-sensor output and water vapor pressure was confirmed through calibration experiments. To compensate for the effect of water vapor pressure on O2-sensor measurements, O2 concentration was expressed on a dry air basis using the confirmed linear relationship. In situ O2-sensor output expressed on a dry air basis was found to follow trends of gas samples analyzed by gas chromatography with good agreement.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Similar Papers
More From: Journal of the Air & Waste Management Association
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.