Abstract

The objective of this study is to evaluate the ability of dynamic contrast enhanced computed tomography (DCE-CT) to assess intratumor physiological heterogeneity in tumors with different angiogenic phenotypes. DCE-CT imaging was performed on athymic nude mice bearing xenograft wild type (MCF-7(neo)) and VEGF-transfected (MCF-7(VEGF)) tumors by using a clinical multislice CT, and compared to skeletal muscle. Parametrical maps of tumor physiology--perfusion (F), permeability-surface area (PS), fractional intravascular plasma (f(p)), and interstitial space (f(is))--were obtained by fitting the time-dependent contrast-enhanced curves to a two-compartmental kinetic model for each voxel (0.3 x 0.3 x 0.75 mm(3)). Mean physiological measurements were compared with (positron emission tomography (PET) imaging, and the spatial distribution of tumor vasculature was compared with histology. No statistically significant difference was found in mean physiological values of F, PS, and f(p) in MCF-7(neo) and muscle, while f(is) of MCF-7(neo) was a factor of two higher ( p < 0.04). MCF-7(neo) tumors also showed a radial heterogeneity with significant higher physiological values in periphery than those in middle and core regions ( p < 0.01 for all physiological parameters). MCF-7(VEGF) tumors demonstrated significant increases in all physiological parameters compared with MCF-7(neo) tumors, and a distinct saccular heterogeneous pattern compared with MCF-7(neo) and muscle. Both PET imaging and histological results showed good correlation with the above results for this same mouse model. No statistically significant difference was found in the mean perfusion and intravascular volume measured by PET imaging and DCE-CT. Increases in cross-sectional area of blood vessels ( p < 0.002) were observed in MCF-7(VEGF) tumors than MCF-7(neo), and their spatial distribution correlated well with the spatial distribution of f(p) obtained by DCE-CT. The results of this study demonstrated the feasibility of DCE-CT in quantification of spatial heterogeneity in tumor physiology in small animal models. Monitoring variations in the tumor environment using DCE-CT offers an in vivo tool for the evaluation and optimization of new therapeutic strategies.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.