Abstract

A diagnostic technique that is based on measuring the ratios of neutral-helium line strengths has been developed for peripheral distributions of electron temperature and density of tokamak plasma. The main components of the technique are a four-channel filter-lens imaging polychromator (FLIP-4) and a Phantom Miro M110 high-speed camera for recording the images. The polychromator has been assembled, adjusted, and tested on an optical test bench. The optical system was installed on the spherical Globus-M tokamak. Some preliminary experiments were carried out. Images of the plasma-gun jet were obtained at neutralhelium lines.