Abstract

Thermometer accuracy at small rise in temperature leads to increasing the knowledge about products process especially in drying of plants, fruits and biological laboratories. This developed model a thermometer based on capacitance change resulting from deflection of a bimetal cantilever. The effect of fringing field is included in the model. The deflection of the theoretical model is simulated and results are shown to closely follow the previously published results. Finally, the complete theoretical model, including the effect of fringing field, is simulated using an example. The Taguchi method with analysis of S/N ratio is used to obtain the optimal design of the sensor. Using the optimum settings, the S/N ratio improved by 24.11 dB.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.