Abstract

We present results of studying the spatial variation of parameters of the electrical response to a weak impact under stepwise loading of concrete beams reinforced with steel rods. It is proposed to use the following diagnostic parameters to characterize the presence of a defective area in reinforced beams: the maximum coefficient of correlation between the spectrum of electrical signal after stepwise loading and the original spectrum; the frequency shift for which the maximum correlation coefficient is observed; the coefficient of correlation between the spectrum of signal at the current loading stage and the signal spectrum at the previous stage; and the center of gravity of the spectrum. The proposed method can be used to locate the defective area in reinforced concrete under bending conditions.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.