The tungsten samples were pre-irradiated with self-ions to create radiation-induced defects and then exposed to the deuterium atomic beam. The deuterium removal was studied by isotopic exchange with atomic hydrogen beam. Modification of the deuterium depth profile in self-ion irradiated tungsten under isotopic exchange up to a depth of 6 μm was measured in- situ by nuclear reaction analysis. The total deuterium retention after isotopic exchange was measured by thermal desorption spectroscopy. It is shown that the efficiency of the deuterium removal increases with increasing of the hydrogen incident flux, incident energy and temperature of the tungsten sample.