Synopsis Sections of 1 × 2 m, sawn from full-size commercial concrete panels, were tested with a microwave moisture meter to establish calibration curves for different types of concrete cladding panel. The tests confirmed that the relationship between microwave attenuation and percentage of absorhed water for such panels was linear, but it was also found that the slope of the curve depended upon the particular construction of the concrete panel. With 10% absorbed water, the microwave attenuation varied between approximately 10 and 20 dB. Anomalous results were obtained during freezing weather and these were attributed to molecular orientation of the water in the concrete.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.