Abstract
The application of antenna arrays (AAs) for obtaining flaw images during automated non-destructive testing is considered. The conventional technique of using an AA as a phased AA has a number of drawbacks. An alternative approach is proposed in which echo signals are registered using an AA operating in the double scanning mode, and a modified algorithm of the combined SAFT, which takes into account multiray ultrasound propagation with consideration of transformations of wave types upon reflections from irregular boundaries of a test object, is used to obtain flaw images. The results of testing a specimen with a model of a volumetric flaw in the form of a 2-mm-diameter side hole drilled at a depth of 12 mm and a specimen with a crack model with a tip at a 12-mm depth are presented. Both specimens have rough bottoms. The obtained images allow determination of not only the dimensions and locations of flaws, but also their type.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.