Abstract

In electroplating, the broad role of cathode and anode is often neglected. This study aims to simultaneously prove the electric current in the three pairs of probes in the cathode-anode direction. It also describes the effect of variations in the anode-cathode area ratio. This result proves that the greater the ratio, the greater the current density in all pairs of probes. Data retrieval used a current sensor current probe DCP-BTA Vernier displayed on a computer screen with the help of Logger Pro software. The results in the study show that the current at every point in the measurement has a less identical graph. In electroplating, nickel (Ni)-1 has a relatively constant amplitude than nickel (Ni)-2. The variation of the anode area ratio at the first nickel (Ni) is 1: 0.821. The ratio of the anode area to the second nickel (Ni) is 1: 0.343. From the analysis results, the first nickel (Ni) has a relatively constant amplitude compared to the second nickel (Ni).

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call