Abstract

Probabilistic cost analysis determined the cost benefit for applying a protective coating to the wetted surfaces of stainless steel tank walls for concentrating solar power (CSP) thermal storage applications. The model estimated the total material cost of coated 347 or 310 stainless steel (347/310) and the cost of uncoated Inconel 625, which served as the reference tank wall cost. Model results showed that the cost of the coated 347/310 stainless steel was always statistically less than the cost of the bare Inconel 625 when these materials are used for tank walls at representative tank diameters and temperatures for CSP storage applications.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have