Abstract
The theoretical analysis shows that if the assumption of the constant tray efficiency of a rectification column is included in the mathematical model, the relation between thermal input and reflux ratio has a character of an unambiguous and monotone function. The conclusions from the considerations are supported by the results of the calculation of the above mentioned relation on an analogue computer for the case of a three-tray rectification column. The ambiguity, if any, will be intercepted in the mathematical model only, if the dependence of the tray efficiency on the load of the rectification column is regarded by us.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.