Abstract
BackgroundTemplating is a preoperative planning procedure that improves the efficiency of the surgical process and reduces postoperative complications of total hip arthroplasty (THA) by improving the precision of prediction of prosthetic implant size. This study aimed to evaluate the accuracy of the preoperative cup and stem size digital 2D templating of THA with mediCAD® software and find the factors that influence the accuracy, such as indication for surgery, patients’ demographics, implant brand, and the assessors’ grade of education.MethodsWe retrospectively retrieved 420 patient template images of all patients who underwent THA between March 2018 and March 2021. Templating of all included images was processed using mediCAD® software a day before surgery by a newcomer physician to hip arthroplasty course (PGY-2 orthopedic resident or hip surgery fellow). Preoperative templating cup and stem sizes were compared with the actual inserted implant sizes.ResultAfter excluding ineligible patients, this study included 391 patients, 193 (49.4%) males and 198 (50.6%) females with a mean age of 43.3 ± 14.9. The average cup sizes predicted before and after surgery were 52.12 ± 14.28 and 52.21 ± 15.05 respectively, and the mean delta cup size (before and after surgery) was 2.79 ± 2.94. The delta stem size before and after surgery has a mean value of 1.53 ± 1.49. The acetabular cup components, measured within ± 0, ± 1, and ± 2 sizes, were 28.9%, 63.9%, 83.1% accurate, respectively. The femoral stem design component measured within ± 0, ± 1, and ± 2 sizes were 27.2%, 61.0%, 78.6% accurate, respectively. Wagner Cone® stem brand, DDH patients, and females showed significantly higher accuracy of stem size templating. Revision THA has the lowest accuracy in terms of cup size templating. The compression of accuracy rate between resident and fellow revealed no significant differences. Also, no significant difference was detected between the accuracy of templating performed in the first months with the second months of the arthroplasty course period.ConclusionOur study showed that under mentioned condition, templating using mediCAD® has acceptable accuracy in predicting the sizes of femoral and acetabular components in THA patients. Digital software like mediCAD® remains favorable because of the short learning curve, user-friendly features, and low-cost maintenance, leading to level-up patient care and THA efficacy. Further studies are necessary for clarifying the role of the assessor’s experience and expertise in THA preoperative templating.Level of evidenceLevel III (retrospective observational study).
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.