Abstract

The polarity of epitaxial AlN film grown on (0001)6H-SiC and dislocation core structures in the film have been studied using a 200 kV LaB6 high-resolution transmission electron microscope of point resolution about 0.2 nm. A posterior image processing technique, the image deconvolution, was utilized to transform a single [21¯1¯0] image that does not intuitively represent the structure into the projected structure map. The adjacent Al and N projected atomic columns with the interatomic distance 0.109 nm can be distinguished from each other by analyzing the image contrast change with the sample thickness based on the pseudo-weak phase object approximation. This makes possible to derive the polarity and core structures of partial dislocations in the epitaxial AlN film at atomic level from a single image without relying on any other additional structure information. The atomic configurations for two partial dislocations containing a 10-atom ring and a 12-atom ring, respectively, have been attained. The method is available for II-VI and other III-V compounds. Its principle and procedure are briefly introduced.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.