Abstract

AbstractAn experimental study was conducted to assess the possibility of determining particle holdup by measuring the pressure drop of a conventional cyclone used in a circulating fluidized bed (CFB) boiler. It was found that within a wide range of inlet solid concentrations, i.e., 0.54–4.42 kg/kg‐gas, the cyclone pressure drop increased linearly with inlet solid concentration at a given gas velocity, while the pressure drop between the dust exit and the vortex finder of the cyclone remained almost constant. Since particle holdup increases virtually linearly with solid flow rate, the particle holdup in the cyclone can be derived from the cyclone pressure drop, and therefore, an equation set was proposed to calculate the particle holdup from the cyclone pressure drop.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.