Abstract
In developing latent prints on cartridge casings and shotgun shells, multiple chemical processes should be used in order to obtain the best results. In Phase I, this study established an optimal chemical sequence for both Brass and Nickel cartridge casings based on six sequences involving four chemicals: Cyanoacrylate, Black Powder, Rhodamine 6G and Acidified Hydrogen Peroxide. Phase II was a validation study of Phase I involving a random sample of both Brass and Nickel cartridge casings, which were processed according to the determined optimal sequences. In addition, ribbed shotgun shells were processed under Phase I results and determined to be dependent upon the utilization of a CrimeScope at 515 nm. Consideration should be given to the type of cartridge case being examined. Although limitations exist, some chemical sequences undeniably work better than others. All photographs were manipulated with Adobe Photoshop. All results were verified by a senior latent print examiner.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.