Abstract

A simple method to determine zoledronic acid and impurities in drug by ion chromatography with conductivity detection was developed. Target analytes have been sufficiently separated from each other on an Ionpac AS19 by using potassium hydroxide as eluent with a self-regeneration suppressor. This novel proposed method enables direct analysis of zoledronic acid in injection sample and provides good resolution. This novel method also exhibits satisfactory precision (less than 1.68%) and accuracy (90.0% - 110.0%), good linearity (r2 = 0.9993 - 0.9999) and sufficient sensitivity (0.007 - 0.030 μg/mL). It can be easily and conveniently adopted for the routine quality control analysis.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.