Abstract
The electron beam machine was installed in 1991 at Nuclear Malaysia Agency. There are about one million meters of wire and cable irradiated in the facility every year. Electron beam irradiation introduces to crosslink the polymer material for high-performance wire and cable for the automobile industry. ALURTRON is facing few challenges while of irradiating wire and cable to determine the speed and to comply with the product quality (QC) test. The uncertainty of Wire Under Beam Handling System (WUBHS) speeds while irradiating wire and cable due to different situations. In this study, Polyethylene (PE) and Polyvinylchloride (PVC) wire and cable irradiated with electron beam irradiation at suitable speed based on the material, size and calculation etc. The sample analyse with hot set and gel content test. The speed decided at range 220-232, 180-196 and 180-194 m/min for 6.4 mm tube, 9.5 mm tube and PVC wire respectively.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: IOP Conference Series: Materials Science and Engineering
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.