Abstract

High-performance liquid chromatography technique was used to estimate valsartan in its pure form and in some pharmaceutical preparations. It was found through the results obtained that the proposed method is sensitive and accurate, and the estimation was done in a short time. In this work, a No L1, 150mm separation column was used to separate the components as they were type The UV spectrometer was used as a wavelength of 239 nm, the column temperature was 40°C, and the mobile phase consisted of 50:50 (acetonitrile: methanol: drops of triethylamine, pH = 2.4) at a flow rate of 1 ml/min. Through what was reached, we find that the method is sensitive, accurate and compatible, as the percentage recovery reached (100.63-103.35), and the linearity was (40-120 mcg/ml) for valsartan. The method was applied to a number of pharmaceutical preparations available in the local market, and the method was successful in the quantitative estimation of valsartan.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.