Abstract

The second morning urine of 207 patients with various renal diseases was examined. After testing the urine with the Combur-9-RL ® dip strip, the concentrations of total protein, creatinine, albumin, α-1-microglobulin, immunoglobulin G and transferrin were determined. The urinary protein fractions were measured in parallel with the electrophoresis kits: Hydragel-Proteinuria (sebia GmbH, Fulda); Protur-HiSi (Beckman Coulter GmbH, Krefeld); SPE-II (Beckman Coulter) and the protein concentrations were calculated. The method comparison was based on the agreement of the ascertained types of proteinuria, and on comparison of the electrophoretically obtained albumin protein concentrations with the automated concentration results. It could be shown that urine electrophoresis is a reliable analytic method for the diagnosis of proteinurias. A good agreement and significant correlations were found between single protein determination and urinary electrophoresis. A diagnostic strategy that combines electrophoresis, single protein determination and immunofixation is useful for the diagnosis and differentiation of proteinuria.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.