Abstract

8-Hydroxy-2'-deoxyguanosine (8OHdG) has been considered as an excellent marker of oxidative DNA damage associated with age-related diseases such as cancer. In this paper, two sensitive methods-capillary electrophoresis with electrochemical detection (CE-ECD) and gas chromatography/mass spectrometry (GC/MS) were developed for urinary 8OHdG analysis. The R.S.D. of the spiked recovery of the two methods for determining urinary 8OHdG was 4.03% and 8.25%, respectively, and the results from the two methods have a good consistency (r=0.999, P<0.01). The developed CE-ECD method was applied to investigate the urinary 8OHdG levels in different cancer patients and follow up the response of therapy. It was found that the excretion levels of urinary 8OHdG in cancer patients were significantly higher than those in healthy persons (35.26+/-27.96 nM versus 13.51+/-5.08 nM, P<0.05), and cancer patients receiving surgical therapy and chemotherapy showed a significant decrease in urinary 8OHdG.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.