Abstract

BackgroundPerchlorate contamination of water and food poses potential health risks to humans due to the possible interference of perchlorate with the iodide uptake into the thyroid gland. Perchlorate has been found in food and drinking, surface, or swimming pool waters in many countries, including the United States, Canada, France, Germany, and Switzerland, with ion chromatography (IC) being the preferred analytical method. The standardization of a robust ion chromatographic method is therefore of the high interest for public health and safety. This article summarizes the experiments and results obtained from analyzing untreated samples, considering the sample’s electrical conductance as guidance for direct sample injection as described in EPA 314.0.ResultsThe suitability of ion chromatography with suppressed conductivity detection was tested for water samples in order to check the influence of matrix effects on the perchlorate signal of untreated samples. A sample injection volume of 750 μL was applied to the selected 2 mm IC column. The IC determination of perchlorate at low µg/L levels is challenged by the presence of high loads of matrix ions (e.g., chloride, nitrate, carbonate, and sulfate at 100 mg/L and above). Perchlorate recovery is impaired with the increasing matrix ion concentrations, and its chromatographic peak is asymmetric particularly at low perchlorate concentrations. The identification of the individual maximum concentration of interfering anions like chloride, nitrate, and sulfate that influence perchlorate recovery helps to reduce the number of sample preparation steps or an obligatory measurement of the electrical conductivity of the sample. Within the scope of this study, samples containing less than 125 mg/L of either anion did not need sample preparation.ConclusionThe identification of the maximum concentration of interfering anions like chloride, nitrate, and sulfate influencing perchlorate recovery provides a simplified alternative to the EPA 314.0 method. This approach reduces unnecessary sample preparation steps while allowing a reliable prognosis of possible interferences and maintaining result quality. This study was performed to support the development of a respective international standard, which is being established by the International Organization for Standardization (ISO). The results of the study are also intended to be used as guidance for interested laboratories to optimize the analytical workflow for trace perchlorate determination.

Highlights

  • Perchlorate contamination of water and food poses potential health risks to humans due to the possible interference of perchlorate with the iodide uptake into the thyroid gland

  • For hydrophobic columns, leading to an asymmetric perchlorate peak, the peak Gaussian factor (PGF) value will significantly deviate from the optimal symmetric peak with, PGF = 1

  • All samples showing conductivity below 1750 μS/cm should be suitable for direct injection, and sample with conductivities above would need to be treated. In contrast to this prognosis the results of our work showed poor perchlorate recovery below 80%, even for samples starting at a concentration of about 100 mg/L matrix ions (MI) or 1000 μS/cm

Read more

Summary

Results

The suitability of ion chromatography with suppressed conductivity detection was tested for water samples in order to check the influence of matrix effects on the perchlorate signal of untreated samples. The IC determination of perchlorate at low μg/L levels is challenged by the presence of high loads of matrix ions (e.g., chloride, nitrate, carbonate, and sulfate at 100 mg/L and above). Perchlorate recovery is impaired with the increasing matrix ion concentrations, and its chromatographic peak is asymmetric at low perchlorate concentrations. The identification of the individual maximum concentration of interfering anions like chloride, nitrate, and sulfate that influence perchlorate recovery helps to reduce the number of sample preparation steps or an obligatory measurement of the electrical conductivity of the sample. Within the scope of this study, samples containing less than 125 mg/L of either anion did not need sample preparation

Conclusion
Background
Results and discussion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call