Abstract

High resolution inductively coupled plasma mass spectrometry (HR-ICP-MS) was applied for multielement-determination in high-purity copper (approx. 99.99%). The samples were introduced into the instrument by three different introduction systems, which were studied with respect to high accuracy, low detection limits and fast analysis: continuous nebulization (CN), flow injection analysis (FIA) and laser ablation (LA). The trueness of the applied method was checked by the analysis of high-purity copper reference material (BCR Cu074). All values obtained for this CRM using CN were in the range of the stated uncertainty for the 9 elements determined: Ag, As, Bi, Cr, Fe, Ni, Pb, Sb, and Sn with contents in the range of 0.5–13 μg/g. Another approach for checking the trueness of the method was to compare the results obtained by this method characterizing the purity of a 4N (99.99% copper content) copper material with those obtained by application of electrothermal atomic absorption spectrometry (ET-AAS) and inductively coupled plasma optical emission spectrometry (ICP-OES). For further characterizing, the concentrations of 49 elements were found in this material below detection limits of HR-ICP-MS in the range of low μg/kg and sub μg/kg. The combination of HR-ICP-MS and a flow injection analysis system (FIAS) improved the robustness of the system in regard to high matrix concentrations. Therefore, matrix concentrations up to 4 g/L could be used for liquid analysis and detection limits were lowered by a factor of 2–5. A calibration method for bulk analysis with laser ablation was developed with doped copper powder as pressed pellets for calibration standards. This method proved to be an excellent fast semi-quantitative method, which was less time consuming in comparison with the analysis of liquids. After application of correction factors the deviation between the results obtained by laser ablation and by analysis of liquids was ≈ 15% for most elements. The method offered the possibility to check for potential losses of analytes occurring during the wet chemical operations.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.