Abstract

A straightforward size exclusion chromatography (SEC) method was developed and validated for the determination of total polivinylpyrrolidone (PVP) in ophthalmic solutions using the unusual combination of size exclusion chromatography (SEC), ultraviolet-visible detection and quantitation of an analyte peak that elutes in the total exclusion volume of the column. Samples of opthalmic solutions are diluted with water and injected onto a TSKgel G1000PW, 7.5 mm i.d. × 30 cm, 12 μm column at 50°C, with 80:20 0.1M sodium acetate-methanol mobile phase and UV detection at 220 nm. Validation was successful for a stability indicating pharmaceutical method, with parameters including specificity, accuracy, linearity, and precision within typical pharmaceutical acceptance criteria. A stress study with acid, base, peroxide, heat, and light indicates that there is no interference from drug, product, or excipients.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.