Abstract

A convenient, reliable and rapid method for the determination of total cysteamine in human plasma by high-performance liquid chromatography with fluorescence detection is reported. This assay involves reduction of samples with dithiothreitol, derivatization of total cysteamine by addition of monobromobimane and protein precipitation by perchloric acid. The calibration curve was linear in the range 2–150 nmol ml −1 and the detection limit was 0.5 nmol ml −1. This method was successfully applied for a pharmacokinetic study of three cysteamine derivatives in healthy volunteers without any interference from coexisting substances.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.