Abstract
HPLC methods described so far for the determination of thiamine and riboflavin in meat samples have used mostly fluorescence detection. The aim of this work was to elaborate a suitable method with UV detection for this purpose and to compare the thiamine and riboflavin contents obtained for meat and liver samples from various pig groups. Homogenized spare rib, chop, ham and fiver samples were treated with acid and heated (at 121°C, 30 min), followed by enzymatic digestion to release the vitamins. After a clean-up procedure the simultaneous determination of thiamine and riboflavin was performed with a Nucleosil ODS (3 μ m) packed column at 45°C. The mobile phase was phosphate buffer (pH 3.0)-acetonitrile (84:16, v/v) containing 5 m M sodium heptanesulphonate. The relative standard deviation was 5% for thiamine and 12% for riboflavin in meat and 8% for thiamine and 5% for riboflavin in liver for four parallel determinations.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.