Abstract

Turbogenerators were and remain the most unreliable element at nuclear power plants in Ukraine. The most dangerous disturbances in the operation of turbogenerators of the TVV type is complete or partial blockage of the hollow conductors of the stator winding. The systems of operational control and technical diagnostics today, in a number of cases, cannot cope with the identification of these phenomena. The complex application of adequate mathematical models, indications of the standard thermal control system and new diagnostic features give the opportunity with sufficient accuracy for practical purposes to detect blockages in the hollow conductors of the stator windings of these turbogenerators. The aim of the work is to develop a program for calculating the three-dimensional temperature field in the rods of the stator winding of a turbogenerator of the TVV-1000-2U3 type, taking into account the temperature field of the stator core, to carry out a test calculation and to compare the experimental and to calculated data. The problem is solved with the help of the finite difference method using the integro-interpolation method.