Abstract
The international method for the determination of the soluble iron content of filter aids has been collaboratively tested by members of the Analysis Committee of the European Brewery Convention to obtain repeatability (r98) and reproducibility (R98) values. It was Judged that precision values were dependent on the quantity of the soluble iron content of the filter aids over the range 32 to 220 mg/kg. Repeatability (r98) value of 0.050 m and reproducibility value (R98) of 0.255 m were obtained over this range.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.