Abstract

The three-phase contact angle (θ) for the system cyclohexane/aniline/quartz has been measured from drop shapes as a function of temperature on approach to the cyclohexane/aniline upper consolute solution temperature Tc. The experiments employed exacting criteria previously established for thermodynamic-quality measurements at fluid interfaces. A first-order wetting transition from partial wetting to complete wetting was observed at a temperature Tw, 2.12 K below Tc. The contact angle vanishes at Tw, scaling as cos θ ∼ |T - Tc|(β1-μ) for T < Tw and cos θ = 1.0 for Tw < T < Tc. The experimental results give a value for β1 = 0.74 ± 0.03, in agreement with theoretical calculations. The data clearly rule out higher order contributions to the change in the contact angle near the critical point for this system. These results are in marked contrast to previous measurements on this system from measurements of capillary rise and meniscus curvature.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.